Single Supply Operation
Input Voltage Range Extends to Ground
Output Swings to Ground while Sinking Current
Guaranteed
Offset Voltage: 50μV Max
Guaranteed
Low Drift: 1.3μV/°C Max
Guaranteed
Offset Current: 0.5nA Max
Guaranteed
High Gain
5mA Load Current: 1.5 Million Min
17mA Load Current: 0.8 Million Min
Guaranteed
Low Supply Current: 520μA Max
Supply Current can be Reduced by a Factor of 4
Low Voltage Noise, 0.1Hz to 10Hz: 0.55μV
P-P
Low Current Noise—
Better than OP-07: 0.07pA/rtHz at 10Hz
High Input Impedance: 250M Ohm Min
Minimum Supply Voltage: 2.7V Min
典型應(yīng)用
典型應(yīng)用
描述
The LT?1006 is the first precision single supply operational amplifier. Its design has been optimized for single supply operation with a full set of specifications at 5V. Specifications at ±15V are also provided.
The LT1006 has a low offset voltage of 20μV, drift of 0.2μV/°C, offset current of 120pA, gain of 2.5 million, common mode rejection of 114dB and power supply rejection of 126dB.
Although supply current is only 340μA, a novel output stage can source or sink in excess of 20mA while retaining high voltage gain. Common mode input range includes ground to accommodate low ground-referenced inputs from strain gauges or thermocouples, and output can swing to within a few millivolts of ground. If a higher slew rate (in excess of 1V/μs) or micropower operation (supply current down to 90μA) is required, the operating currents can be modified by connecting an external optional resistor to Pin 8.
For similar single supply precision dual and quad op amps, please see the LT1013/LT1014 datasheet. For micropower dual and quad op amps, please see the LT1078/LT1079 data sheet.